R1000TR Series Load Bank
The Model ULB-R1000 TR is a state-of-the-art, high capacity trailer-mounted resistive load bank system intended for testing and routine maintenance of stand-by generators, UPS, or other AC power sources. Designed for mobile outdoor use, the ULB-R1000 load bank features horizontal hot-air discharge to keep the overall height to a minimum.
- Technical Details
- Physical Specifications & Inbuilt Safety
- Features & Benefits
- Options
- Applications
- Downloads
Technical Details
Load Bank
R1000 TR Series, Self Contained, Trailer Mounted Load Bank
Load Bank Type
AC Resistive
Load Rating
Rating: 1000kW, Voltage: 480 VAC, Phase: 3 phase, Frequency: 60 Hz, Load Step Resolution: 25kW
Rating: 1000kW, Voltage: 400 VAC, Phase: 3 phase, Frequency: 50Hz, Load Step Resolution: 25kW
Power Factor
1
Install Type
Stationary / Permanent, Outdoor Use, Trailer Mounted
Duty Cycle
Continuous Duty
Cooling System
Horizontal Airflow
Physical Specifications & Inbuilt Safety
Enclosure
Heavy gauge steel with a durable polyester powder coat finish
Environmental Rating
NEMA Type 3R
Approx. Dimensions
99 W x 38.5 D x 70 H (inches)
251 W x 98 D x 178 H (cm)
Approx. Weight
2700 lbs / 1227 Kgs
Inbuilt Safety Features
- Over-voltage/under-voltage/voltage Imbalance protection
- 3 Phase current imbalance protection
- Cooling-air loss protection
- Over-temperature protection
- Internal Fuses for Resistive load element groups
- Load Dump
- Limit Switches for Doors
Features & Benefits
- Digital Controls using In-built PLC – Ease of Operator use, Profile loading, Data Logging
- Powder Coating – Corrosion Prevention and Durability
- Fork truck slots or lifting eyes – Easily movable by fork truck or hoist
- Numerous Safeties – Superior protection of Load Bank / Reliability
- Nichrome “HeliCon” load elements, supported by SS rods – Reliability and Extend Life
- Multiple Load Banks can be daisy chained – Larger capacity loading using this features and using multiple smaller capacity load banks
Options
- Better Load resolution; such as 1kW, 5kW, 10kW
- Better metering accuracy; such as +/-1% F.S
- Certified Drawings
- 25ft or 50ft or longer Coded Load Cable sets
- Power Cable Reel, Motorized
- Longer Control Cable (Up to 100 ft)
- Caster Wheels (all swivel with brakes)
- Arctic Winterizing Kit
- Auto Load Level Modification
- External Power Switch; if control power external opted
- Explosion Proof
- Stainless Steel Fabrication
- Vinyl Dust Cover
- Without HMI (No Display)
Applications
- Back up Generators
- Emergency facilities – Health Care
- Manufacturing
- Telecom
- Banking, Finance and Insurance