R1000 Series Load Bank
The model ULB-R1000 is a compact , versatile 1000kW stationary / permanent load bank for testing back up generators, UPS systems, Ground Power Units and Any other power source. The load bank can be used to test any loads up to a maximum of 1000kW at 480V and also at other voltages such as 400 V, 600 V with derating.
- Technical Details
- Physical Specifications & Inbuilt Safety
- Features & Benefits
- Options
- Applications
- Downloads
Technical Details
Load Bank
R1000 Series, Self Contained, Stationary / Permanent Load Bank
Load Bank Type
AC Resistive
Load Rating
Rating: 1000kW, Voltage: 480 VAC, Phase: 3 phase, Frequency: 60 Hz, Load Step Resolution: 25kW
Rating: 1000kW, Voltage: 400 VAC, Phase: 3 phase, Frequency: 50Hz, Load Step Resolution: 25kW
Rating: 1000kW, Voltage: 600 VAC, Phase: 3 phase, Frequency: 60Hz, Load Step Resolution: 25kW
Power Factor
1
Install Type
Stationary / Permanent, Outdoor Use
Duty Cycle
Continuous Duty
Cooling System
Air Cooled, Vertical Airflow
Physical Specifications & Inbuilt Safety
Enclosure
Heavy Gauge Steel Powder coated
Environmental Rating
NEMA Type 3R
Approx. Dimensions
46 W x 58 D x 85 H (inches)
117 W x 147 D x 216 H (cm)
Approx. Weight
1800 lbs / 816 Kgs
Inbuilt Safety Features
- Over-voltage/under-voltage/voltage Imbalance protection
- 3 Phase current imbalance protection
- Cooling-air loss protection
- Over-temperature protection
- Internal Fuses for Resistive load element groups
- Emergency Switch
- Load Dump Switch
Features & Benefits
- UL & cUL Listed – Guaranteed Quality
- Digital Controls using In-built PLC – Ease of Operator use, Profile loading, Data Logging
- Handheld Touch screen HMI with 25 ft – Reliable, Ease of operation from one screen
- Powder Coating – Corrosion Prevention and Durability
- Fork truck slots or lifting eyes – Easily movable by fork truck or hoist
- Numerous Safeties – Superior protection of Load Bank / Reliability
- Nichrome “HeliCon” load elements, supported by SS rods – Reliability and Extend Life
- Multiple Load Banks can be daisy chained – Larger capacity loading using this features and using multiple smaller capacity load banks
Options
- Better Load resolution; such as 1kW
- Better metering accuracy; such as +/-1% F.S
- Certified Drawings
- Longer control cable (up to 100 ft.) for HMI control
- 25 ft. and 50 ft. or longer color coded Load Cable sets
- Power Cable reel, Motorized
- Automated Control
- Caster Wheels (all swivel with brakes)
Applications
- Better Load resolution; such as 1kW
- Better metering accuracy; such as +/-1% F.S
- Certified Drawings
- Longer control cable (up to 100 ft.) for HMI control
- 25 ft. and 50 ft. or longer color coded Load Cable sets
- Power Cable reel, Motorized
- Automated Control
- Caster Wheels (all swivel with brakes)